DOORS AND HATCHES

1


  TECHNICAL DATA
1.7

  GADAM TYPE
1.7.2

  DESIGN 3 DOOR WITH TOUCHING SEAL A0 - A60
1.7.2.6.A

GADAM 3

Heavy Duty, single leaf, sliding, external weather tight fire door.

Doorleaf:
Painted mild steel (offshore paint system) or stainless steel, box type, ceramic fibre core.

Doorframe:
Painted mild steel (offshore paint system) or stainless steel. The standard frame is bolted to the bulkhead/wall, optional: welded. Weather hood included.

Hardware:
Heavy duty stainless steel.


Download PDF


  Main performances characteristics Standard Enhanced  

  Fire Rating A0 - 60 A0 - 60  
  Door leaf plate thickness 2 mm mildsteel 2 or 3 mm stainless  
  Door leaf total thickness 80 mm thickness 80 mm thickness  
  Frame 5 mm mildsteel 5 mm stainless  
  Weight (900 x 2100) frame included 280 kg Depends on size  
  Sound reduction Rw = 39 dB Rw = 39 dB  
  Gas Tightness 300 l/hr/m @ 50 Pa 300 l/hr/m @ 50 Pa  
  Thermal Insulation U = 0.8 W/m2K U = 0.8 W/m2K  
  Clear Opening 900 x 2100 Customised  
  Blast Resistance Up to 0.1 bar Up to 2 bar  


Options


Vision Panel 200x500
Release Handle
Air Break

Dimensions