DOORS AND HATCHES

1


  TECHNICAL DATA
1.7

  GADAM TYPE
1.7.2

  DESIGN 1 DOOR WITH TOUCHING SEAL A0 - A60
1.7.2.1.A

GADAM 1

Heavy Duty, single leaf, hinged, external weather tight fire door.

Doorleaf:
Painted mild steel (offshore paint system) or stainless steel, box type, ceramic fibre core. Reinforced for the hinges, door closer and the optional panic bar.

Doorframe:
Painted mild steel (offshore paint system) or stainless steel. The standard frame is bolted to the bulkhead/wall, optional: welded.

Hinges:
Welded 3 off, enhanced: a continuous hinge, bolted.

Hardware:
Heavy duty stainless steel.


Download PDF


  Main performances characteristics Standard Enhanced  

  Fire Rating A0 - 60 A0 - 60  
  Door leaf plate thickness 2 mm mildsteel 2 or 3 mm stainless  
  Door leaf total thickness 80 mm thickness 80 mm thickness  
  Frame 4 mm mildsteel 4 or 5 mm stainless  
  Hinges 3 hinges of 150 mm Continuous Hinge  
  Latch 1 point 3 point  
  Weight (900 x 2100) frame included 165 kg Depends on size  
  Sound reduction Rw = 39 dB Rw = 42 dB  
  Gas Tightness 300 l/hr/m @ 50 Pa 300 l/hr/m @ 50 Pa  
  Thermal Insulation U = 0.8 W/m2K U = 0.8 W/m2K  
  Clear Opening 900 x 2100 Customised  
  Blast Resistance Up to 0.1 bar Up to 2 bar  


Options


Vision Panel 200x500
Panic Bar
Wind Break

Dimensions